Izoprofil.com helps you compare materials for a specific building project. The guides cover the uses of sandwich panels, PIR insulation boards, metal roof tiles and trapezoidal sheets. The criteria depend on the application, including the supporting structure, thermal performance and requirements for the finished surface. Read the product specifications, identify which dimensions affect the order and compare complete solutions. The articles help you discuss the options with a designer or installer and check the suitability of the selected materials before purchase.

Choosing a roofing membrane to suit the roof build-up and loft use

First decide which side of the roof build-up the membrane will serve, rather than relying on a trade name. Check its diffusion resistance, watertightness, strength and the permitted substrate and gaps. Grammage alone does not confirm suitability. For a habitable loft, pay attention to the airtightness of the inner layer; for metal cladding, to drainage and ventilation. Compare the requirements with the cladding instructions and the build-up design. Only then ask about accessories and the compatibility of the whole system.

Which sandwich panels should you choose for the walls and roof of a house?

In a residential house, wall and roof panels are meant to form a sealed envelope together, but they perform different tasks. Choosing the core is only part of the decision. Thermal requirements, quiet inside, fire protection and the method of support must be combined. It is best to do this before fixing openings, the eaves and the routing of services. A panel with two metal facings and an insulating core is a different product from a thermal insulation board alone. For the façade, the wall variant is selected, and for the roof slope, the roof variant with the appropriate profile and joint. Whether they can be used in a house depends on the design and the documents for the specific products. The PIR or mineral wool designation alone does not settle this question.

BauderPIR FA: price per square metre and effective coverage

The price per metre of BauderPIR FA should refer to a clearly defined area: the external dimension of the board or the effective coverage after the laps are laid. These quantities are not equal, which is why an identical number of sheets does not always cover the area entered in the cost estimate. To compare offers, a row plan with perimeter strips, openings and cut-offs is needed. Also check whether the seller states the number of pieces, the nominal area or the coverage area of the pack. The example below separates the two methods of calculation. We then indicate how to add waste, accessories and labour so that the final cost relates to the entire roof slope and not just the delivery.

Which roof covering suits your house?

The choice of roofing is determined above all by the roof pitch, the structure and shape of the roof, and how the attic will be used — not by appearance or price per square metre alone. Check whether the chosen system holds the required approval for the specific pitch, how the substrate and joints are resolved, and whether the trade name really corresponds to the given profile. When replacing a covering, inspect the roof trusses and allow for loads from snow, wind and any photovoltaic installation. Compare two full quotations for the same project, covering flashings, fixings, transport and labour.

What distinguishes modern modular tile-effect roofing sheets?

Modern modular metal roof tiles stand out for their repeatable sheet format and refined joining method, not for the label ‘new’ alone. Before choosing, check the effective dimensions—the coverage area rather than the overall size—as well as the profile geometry and the type of lock. View several joined sheets in natural light, because a single sample does not show the rhythm of the whole roof slope. Also ask about the permissible roof pitch and the details at the eaves. A flat profile does not remove the need for an even substructure, and a deeper pressing is not automatically better.

Which PIR board under render suits a house built from aerated concrete?

Aerated concrete can provide a significant part of a wall's thermal resistance, so the insulation is matched to the specific type of masonry. For a rendered façade, the compatibility of the PIR board with the whole system is equally important. A favourable lambda is not enough if the substrate, render, adhesive and fixings have not been planned as one assembly. The width of the block alone does not indicate its thermal performance. Density, thermal parameters and the jointing technology matter. The calculations require data specific to the actual wall layer, not a general 'aerated concrete' entry. A different type of the material at the same thickness will give a different resistance.