Roof quotations with swissporPIR Alu: fixings and protective layers

At a glance

For a flat roof with swissporPIR Alu, the price of the board with adhesive alone does not cover the entire task. The quotation should include the required fasteners and the execution of all outlets and edges. Compare quotations for the same cross-section and standard of work protection. The board is the thermal insulation layer; the gas-tight laminate protects the PIR core, it does not replace the covering. The terms “polyurethane boards” and “polyurethane foam” are broader than the PIR product designation. When requesting delivery, state the flat roof build-up on the specific substrate, which you will have identified beforehand.

Illustration of a PIR board with an auxiliary grid when pricing fixings and roof-layer protection

PIR boards on a suitable roof substrate

The name alone from the price list is not enough, because the same board requires different support details and substrate preparation. The choice should lead to a complete cross-section with vapour control layer, roof drainage and covering. Give all tenderers the layer description and the actual parameters of the fixing location so that the prices relate to a similar task.

Layer thickness and designed falls

Lambda 0.022 W/(m·K) allows the required thermal resistance to be achieved within a limited height, which counts in a flat roof at parapets and thresholds. When comparing polyurethane boards, check the height of swissporPIR Alu at the outlet and at a limited parapet.

Before comparing amounts, link the thickness of swissporPIR Alu to the designed fall geometry. The manufacturer prohibits cutting this board in thickness to form the area at the outlet, so a cheaper item may produce a different result. Resolve drainage before assessing the amount, without arbitrarily reducing the thermal insulation layer. In the tender table, include the fall design and the minimum and maximum height of the entire assembly, and link the price difference to a specific change in parameters.

Polyurethane insulation on profiled metal sheeting

The boards are laid with offset joints. The instructions give single- and two-layer solutions, and for one layer recommend milled or tongue-and-groove edges. The bill of quantities for the polyurethane insulation then includes the staggered swissporPIR Alu joints over the trapezoidal metal deck.

When calculating quantities, the support of swissporPIR Alu must be matched to the upper flanges of the metal deck and to the board thickness. The area of a rectangle can be misleading, because a photograph of a finished roof surface does not confirm the permissible bearing in a different roof. The cutting plan must allow one or two layers to be laid in accordance with the adopted solution. For the quotation, add the substrate cross-section, the joint plan and the edge variant from the design, so that the necessary details do not fall outside the scope.

Mechanical fixing also when bonding

In the swissporPIR Alu instructions, bonding does not exempt from mechanical fastening. When assessing the completeness of the purchase, indicate this fastening in the solution with adhesive.

The mechanical fastening required by the instructions remains in the quotation even when swissporPIR Alu is bonded. An omitted item does not remove the task, because bonding this product does not exempt from fasteners and does not provide rules identical to another system. The delivery of supplementary materials must allow the number and arrangement of fastenings to be matched to the specific roof. Before approving the amount, agree the zone layout, the fastener parameters and the compatibility of the waterproofing with the system and the scope of execution of the connections.

Condition of the boards before the waterproofing is installed

Dry and undamaged boards are used in the construction; the instructions do not permit damp insulation to be built into the roof system. When proposing a substitute, assess the moisture condition of swissporPIR Alu before the tight covering closes the layers.

Assessing the substitution requires checking that the swissporPIR Alu is dry and undamaged before the covering is installed. A similar name does not give full equivalence, and low water absorption does not mean that damp insulation may be built in. The tenderer’s data should allow the layers to be closed only once the necessary material conditions have been met. In both quotations, compare the acceptance of the boards and the separate fire assessment of the complete roof assembly before you accept the change of solution.

Polyurethane insulation: rebates, edges and scope of works

The roof cost estimate should itemise the preparation of the substrate, the insulation, the fasteners, the adhesives, the waterproofing and the details, with particular attention to the outlets and the bases of equipment. The budget then also covers the cost of and responsibility for these elements and the terminations of the swissporPIR Alu.

Before approving the price, separate the regular swissporPIR Alu field from the repeated details of drains and equipment. The material price does not show the result when a small error at every opening covers a significant part of a large project. A complete schedule should allow the bill of quantities and the acceptances to be linked to the actual geometry and the sequence of works. In the order, confirm the list of auxiliary materials and the inspection plan before the joints are covered, and price the missing works as separate items.

A case worth considering

In a quotation for a flat roof with swissporPIR Alu, the fasteners must also be priced, even though the supplier specifies adhesive bonding. The requirement for mechanical fastening translates into material and labour. Outlets, edges and protection of the works against the weather should be separate items; omitting them only lowers the initial amount. Quotations should therefore be compared for the same completed and compliant roof assembly.

7 branches. Materials closer to your project.

Izoprofil.com map of seven branches offering sandwich panels, PIR boards and sheet metal
  • SEROCK — Dzierżenin 34 E [mapa]
  • BŁONIE — ul. Sochaczewska 138A [mapa]
  • RADOM — ul. Grobickiego 8 [mapa]
  • ŁÓDŹ — Natolin 8 [mapa]
  • OLSZTYN — Barczewo, ul. Prosta 9 [mapa]
  • WROCŁAW — ul. Jerzmanowska 10C [mapa]
  • GORZÓW WLKP. — ul. Zielona 33/34 [mapa]

Check prices and availability: +48 500 409 109

Free quote

Materials for your project