PIR insulation
How many components does a swissporPIR Alu roof require? Scope of the quotation
A roof with swissporPIR Alu is not just a layer of boards above the rafters, but a whole set of components that must be priced together. The PIR core with gas-tight laminate on both sides forms the above-rafter thermal insulation of the pitched roof, but above it remain the protective and fixing layers, and at the eaves, roof valleys and windows there are flashings and the gutter as well. A change in the roof covering level may require these details to be adapted, which is why the quotation should cover the completed refurbishment, not just the material. It is worth comparing these works with the benefit of the preserved attic space. Note the names: “polyurethane boards” and “polyurethane foam” are broader than the PIR product designation, so in a supply enquiry state the above-rafter position of swissporPIR Alu in the roof slope cross-section.

PIR boards in the complete pitched roof assembly
The price-list item covers the board itself, not a finished roof — with the gas-tight laminate, the functions of the outer layers still have to be provided. So that the quotes relate to the same task, give everyone the roof-slope cross-section together with the support solution and the chosen board edge.
The junction between the roof slope insulation and the wall
In the cost estimate for the swissporPIR Alu above-rafter thermal insulation, the termination at the eaves must be checked. The board with a thermal conductivity of 0.022 W/(m·K) allows the layer height to be reduced, and its continuous laying over the timber reduces the gaps caused by the rafter width. However, the thermal benefit also depends on the point to which the insulation has been brought.
Merely covering the timber in the middle of the roof slope does not eliminate the uninsulated strip at the perimeter, which is why the swissporPIR Alu above-rafter insulation must be combined with insulation of the external wall. A cheaper item may produce a different effect if the heat flow through the junction of the wall and roof remains unrestricted. In the quotation table, include the detail of the ring beam, the wall plate and the transition of the layer onto the façade, and link the price difference to a specific change in parameters.
Polyurethane insulation and fixing of the counter-battens
When ordering swissporPIR Alu, separate the cost of the boards from the work of preparing the roof structure. First assess the condition of the timber and the evenness of the rafters or boarding that will support the insulation. Covering a damaged or sagging structure with a board is not repairing it.
Before ordering swissporPIR Alu, measurements of the supporting plane, an assessment of the timber and a layout plan for the fixing screws of the counter-battens are required. Their length and arrangement form part of the quotation scope, as does the preparation of a correct eaves detail. The cutting plan and the number of boards can then be linked to the actual installation. The roof pitch area alone does not reveal the work necessary on a sagging or damaged structure.
Two different routes to protection against moisture
A complete quotation for swissporPIR Alu covers two separate scopes: the roof underlay above the thermal insulation and the sealing on the interior side. For the outer layer, determine the path of water to the eaves. Materials and labour must cover tight laps and the points where fixings pass through.
In the roof costing, separate protection against precipitation from limiting the flow of moist air. The high resistance of the laminate does not close leaks at walls and openings. For both layers, specify the installation sequence, the materials for the laps and the seals at fixings and at the roof window. Only the costing of these connections shows whether the scope is complete.
Summer comfort and the detail at the chimney
Thermal insulation limits heat flow in summer too, but does not guarantee a single temperature in the attic. Window area, shading, ventilation and internal gains are decisive. When proposing an equivalent product, check summer comfort under the roof with swissporPIR Alu as well as the requirements at the chimney.
Assessing the change requires separate consideration of heat gains in the attic and protection at the chimney. A similar name does not give full equivalence: class E does not mean non-combustibility, and insulation does not remove the energy penetrating through the glazing. In both quotations, compare the design for the area around the chimney and the assumptions on shading and air exchange before you accept a change of solution.
Insulation with polyurethane: work beyond the roof slope area
The quotation should cover the change in the height of the roof slope at the eaves, the ridge and the flashings. Check the gutters, the roof valleys and the setting of the windows. In the budget, take into account the effect of swissporPIR Alu on the covering level at the gutter and at the existing window.
Before approving the price, price the ancillary works associated with raising the layers above swissporPIR Alu. The price of the material does not show the result, since maintaining the room height does not mean there are no changes at the outer edge of the roof. The schedule should allow the complete scope to be calculated with flashings and accessories for tight connections. In the order, confirm the measurements of the eaves, ridge, roof valleys and terminations at the roof windows, and price the missing works separately.
A case worth considering
In the calculation for a roof with swissporPIR Alu, the effects of raising the layers above the rafters must be included: gutters, flashings, windows and fixings. Compare the benefit of preserving the attic surface with this scope. The square metres of the board alone do not describe a completed refurbishment, and comparable offers should lead to a similar standard of the interior and complete covering.