Choose a material

Roofing sheets

Sandwich panels

PIR insulation boards

XPS

Accessories

Fencing

PIR insulation

Eurothane G insulation costs: materials and finishing work

At a glance

The price of Eurothane G covers the composite product, but not the entire insulation service. The cost estimate must include preparing the wall, fixing and finishing. Only such a scope can be reliably compared with the variant in which insulation and lining are carried out separately. Recticel Eurothane G consists of a PIR board faced on both sides with a gas-tight facing and 12.5 mm plasterboard. It is intended for suitable internal insulation applications. An enquiry for PIR boards should describe the internal wall lining that connects Eurothane G PIR with 12.5 mm plasterboard. The masonry beneath Eurothane G must be prepared in accordance with its condition and the requirements of the new build-up.

Light plasterboard face and layered section, accompanying the Eurothane G guide — Izoprofil.com

What the quote must identify

Do not choose solely on the basis of a short commercial description, because the factory bonding of the layers does not replace an assessment of the surface to which they are to be fixed. The compared offer should allow the composite to be matched to the existing partition and to the expected use of the interior. Agree with the bidders on the condition of the masonry, the function of the room and the points where the new construction meets the adjacent partitions, so that everyone prices a similar task.

What result is worth paying for

In the Eurothane G data, the lambda value of 0.022 W/(m·K) refers exclusively to the PIR insulation component. When calculating thermal resistance, therefore, the thickness of the plasterboard facing must not be included as if it were part of the PIR core.

In the quotation comparison, separate the total thickness of Eurothane G from the thickness of the PIR component, because the lambda value of 0.022 W/(m·K) describes only the core, not the gypsum facing. Treating the gypsum as if it were foam will overstate the thermal resistance of the composite, so the cheaper item may produce a different effect. Compare the insulation effect with the loss of room space, and in the table state the PIR parameters, the share of the facing and the thermal resistance of the whole variant.

Board format versus actual waste

The Eurothane G board measures 2600 × 1200 mm. Within it, the PIR component has straight edges, while the longer sides of the plasterboard facing are bevelled, which allows joints to be made.

Base the cutting layout of the 2600 × 1200 mm panels on two joint functions: the bevelled long sides of the plasterboard form a visible joint, while the straight edge of the PIR core requires the insulation to be pushed tight. The allowance results from the cutting plan, not from the packaging area, because a correct gypsum joint does not prove that the PIR is in proper contact. When pricing, check the position of the joints, the tight fit of the insulation component and the routing of services.

Is the proposed variant equivalent?

For Eurothane G, classification B-s1,d0 is stated for a specific end use. This does not prove that the PIR foam is non-combustible, nor does it automatically establish the fire resistance of the entire building element.

With a substitute product, check how you will transfer heavy fixings through the composite facing of Eurothane G to the substrate — class B-s1,d0 relates to a specific end use and does not describe the load-bearing capacity of suspended constructions. The supplier should provide data for designing the fixings independently of the fire assessment. A lower price is only a saving if the effect is equal, so compare the anchors, the routing of installations and the documentation of the conditions of use.

Delivery and protection of the purchased material

Internal thermal insulation with Eurothane G boards changes the thermal conditions of the masonry, so the design must provide for the continuity of the gas-tight facings and assess whether the wall will be able to dry out.

Insulating the wall from the inside with Eurothane G changes its temperature and drying conditions, while the external side may remain unchanged. Before covering the masonry, establish the source of the moisture, the necessary protection and the ventilation of the room. In the quotation, also specify the execution of the junctions with the floor and the ceiling. A dry gypsum facing after installation does not prove that the cause of the moisture in the wall has been eliminated.

Full cost of the finished solution

The purchase description for Eurothane G should separate the PIR core thickness, the plasterboard layer and the finishing works. In the bill of quantities, record the number and type of fixings, the materials for joints and the reveals’ terminations. Such a specification allows a complete lining to be accepted, rather than settling unforeseen extras only after the boards are delivered.

Relate the Eurothane G price to the entire wall: preparation and repair of the masonry, fixing, jointing, the perimeter of the lining, the reveals and the relocation of existing installation points. With many openings, short terminations and adjustments can change the amount more than the board surface itself, so add each excluded activity to the schedule as a separate cost. Only a scope closed in this way allows you to assess whether the offer leads to an equally complete internal lining.

For Eurothane G, it is worth breaking the price down into the composite, the wall preparation and the finishing of the joints. Add to this the work at the reveals and installation points. In a room with many openings, these can matter more than in a solid wall. An offer per square metre of uniform lining does not have to include the same activities. The comparison should show the finished scope that can be accepted once the works are complete.

7 branches. Materials closer to your project.

Izoprofil.com map of seven branches offering sandwich panels, PIR boards and sheet metal
  • SEROCK — Dzierżenin 34 E [mapa]
  • BŁONIE — ul. Sochaczewska 138A [mapa]
  • RADOM — ul. Grobickiego 8 [mapa]
  • ŁÓDŹ — Natolin 8 [mapa]
  • OLSZTYN — Barczewo, ul. Prosta 9 [mapa]
  • WROCŁAW — ul. Jerzmanowska 10C [mapa]
  • GORZÓW WLKP. — ul. Zielona 33/34 [mapa]

Check prices and availability: +48 500 409 109

Free quote