Buying termPIR WS: roof covering, fixings and cutting waste

At a glance

A quotation for termPIR WS should refer to the selected roof build-up. The price of the insulation does not automatically include fixings, separating layers and flashings. A comparison only becomes meaningful once the same technical assumptions have been established with all suppliers. termPIR WS consists of a PIR core with a gas-permeable glass fleece facing on both sides. This is a different surface from a gas-tight aluminium laminate. An enquiry for PIR boards should describe the flat roof area on which the board facing is to work together with the covering. The termPIR WS fleece must be linked to the layers and the fixing method of the chosen roof covering.

Illustration of a board with a light silver face, accompanying the guide to buying termPIR WS — Izoprofil.com

What the quotation must identify

Do not choose solely on the basis of a short commercial description, because an identical PIR core does not mean identical adhesion of every facing. The offer being compared should allow the interaction of materials to be agreed before laying begins over a large area. Agree with the bidders the approval of a specific combination of board, fastening layer and waterproofing, so that everyone prices a similar task.

An equal thermal basis for comparison

For termPIR WS, the datasheet distinguishes three thickness ranges: below 80 mm lambda is 0.027 W/(m·K), from 80 mm to below 120 mm — 0.026 W/(m·K), and from 120 to 250 mm — 0.025 W/(m·K). A change in the ordered thickness may therefore require a change of lambda in the thermal comparison.

With a low parapet, the insulation thickness is locally reduced, so for pricing the lambda appropriate to that local thickness must be used, not that of the average roof field. Otherwise the cheaper item may reflect different thermal assumptions in the narrowing required by the geometry of the flashing. In the quotation table, record the actual thickness and the thermal conductivity assigned to it in each analysed section; only then will you link the price difference to the parameters.

Coverage, cutting layout and labour

termPIR WS is offered with a straight edge and with milling, the variant of which depends on the order. Laying requires careful butting of the boards and a stable substrate.

Determine the number of packages from the cutting plan, not from the package area alone, because the milled edges of full boards do not solve the connection to an element of a different shape. The last rows around the roof outlet and the adjacent installation enclosure require cut pieces with stable support and room for correct detailing. Check the arrangement of the cut pieces, the condition of their sides and the feasibility of detailing the outlet before you price the polyurethane insulation.

Parameters required for the application

For termPIR WS, a compressive strength of CS(10/Y)120 is declared. The reaction to fire of the product itself is F for thicknesses of 20–49 mm and E for 50–250 mm.

For an alternative product, check the service zone around equipment installed above the roof layers with termPIR WS: assess the loads together with the support and protective layers before you regard a lower price as a saving with an equal result. The CS120 result does not on its own describe the performance of the system under the constant pressure of the support, and a similar name or facing is not enough. The supplier should present data for assessing the pressure and fire requirements without mixing the properties of the board with the roof classification; also compare the service access and the compatibility of the substrate and covering with the assessed system.

Layers that should not be omitted

The gas-permeable fleece on the surface of termPIR WS does not seal the roof against water. Until the proper covering is laid, the boards remain exposed, so protection during the works is a separate item and not a property of the insulation.

When accepting termPIR WS, pay attention to the condition of the gas-permeable fleece, which is not waterproof. If the works are interrupted before the covering is laid, the exposed boards require protection against rain, and the scope of this protection should be included in the offer. Regarding roof protection, ask who is responsible for securing the day’s work front and whether the boards will remain dry until they are covered with the membrane.

Full cost of the finished solution

The termPIR WS order must specify the thickness, format, edge type and the solution connecting the board to the covering. The selected systems impose a specific adhesive or fixing method, so these details belong in the specification, not in on-site arrangements.

For termPIR WS, compare the quotation for the bonded and the mechanically fixed variant in line with the planned roof, including substrate preparation and work at the perimeter and penetrations. Failure to agree the fixing method changes the quantity and type of auxiliary materials, so the rate per board alone does not reflect the scope of works. When approving the order, check the number of boards according to the actual coverage, the consumption of fixings and the scope of flashings, and record each excluded item as a separate cost.

The termPIR WS quotation should reveal the method of connection to the covering. Different scopes of bonding, fixing and substrate preparation can change the value of the works. The rate per board alone does not show this. Ask for a schedule of auxiliary materials and details at outlets and parapets. That way you compare solutions that lead to the same degree of roof closure.

7 branches. Materials closer to your project.

Izoprofil.com map of seven branches offering sandwich panels, PIR boards and sheet metal
  • SEROCK — Dzierżenin 34 E [mapa]
  • BŁONIE — ul. Sochaczewska 138A [mapa]
  • RADOM — ul. Grobickiego 8 [mapa]
  • ŁÓDŹ — Natolin 8 [mapa]
  • OLSZTYN — Barczewo, ul. Prosta 9 [mapa]
  • WROCŁAW — ul. Jerzmanowska 10C [mapa]
  • GORZÓW WLKP. — ul. Zielona 33/34 [mapa]

Check prices and availability: +48 500 409 109

Free quote

Materials for your project