Choose a material

Roofing sheets

Sandwich panels

PIR insulation boards

XPS

Accessories

Fencing

PIR insulation

Buying Eurothane Silver: price per square metre, coverage and roof costs

At a glance

With Eurothane Silver, a distinction must be made between the purchase area and the finished covered area. Differences may arise from edges and cutting. A reliable quotation should also specify the method of fixing, the complete covering package and the scope of work at the roof terminations. Recticel Eurothane Silver is a PIR board with multi-layer gas-tight foil on both sides and a printed grid. The current data sheet designates it for flat roofs in a classic configuration. An enquiry for PIR boards should describe a classic flat roof for which mechanical fixing, adhesive bonding or ballast is being considered. Eurothane Silver must be assigned to a specific mechanical, bonded or ballasted configuration.

Board with a grid on its silver facing, illustration for a Eurothane Silver assembly — Izoprofil.com

The precise scope of the enquiry

Do not choose solely on the basis of a short commercial description, because the board’s wide range of applications does not mean that components from different systems can be combined arbitrarily. The compared offer is intended to allow one agreed configuration to be selected before the insulation and the waterproof covering are ordered. Agree with the bidders on the substrate, the waterproofing variant and the documentation of how the roof layers are to be joined, so that everyone prices a similar task.

What result is worth paying for

For Eurothane Silver, the declared lambda is 0.022 W/(m·K) across the thickness range of 20–200 mm. However, the thickness of the layer must be derived from calculations for the entire building element, not from the board’s data sheet alone.

In the quotation comparison for Eurothane Silver, record the thickness of the main field, the number and type of fasteners, and the perimeter detail of the thermal insulation. The lambda of 0.022 W/(m·K) alone does not determine the cost, because the R of an equivalent section of board does not include a correction for each fastener penetrating the insulation. Only a calculation of the entire roof with Eurothane Silver shows whether the cheaper item is not based on different thermal assumptions.

Coverage, cutting layout and labour

Eurothane Silver boards come in formats of 600 × 1200 mm and 2400 × 1200 mm, with the 20 mm variant indicated exclusively in the smaller format. Therefore, for the selected thickness, the available format and edge must be determined straight away.

Choose the 600 × 1200 or 2400 × 1200 mm format and the straight edge or rebate together with the thickness, because the 20 mm variant appears in the data sheet only in the smaller format. Calculate the allowance from the cutting plan and the number of obstacles on the roof slope, not from the packaging area alone. In the specification, state the dimension of the supplied board and the covered area so that the polyurethane insulation is priced with this detail.

Is the proposed variant equivalent?

The Eurothane Silver data sheet issued in September 2026 assigns CS150 to boards from 30 mm thick, whereas the 20 mm board has CS120. For reaction to fire, class F applies to the board itself from 30 mm; no performance is declared for the 20 mm version.

For a substitute, compare the correct row of the table: CS120 for 20 mm and CS150 from 30 mm, and after changing the Silver thickness, read off the mechanical data and the scope of the fire declaration again. B-s2,d0 refers to the specified application on sheet metal, not to every free-standing board, so a similar name or facing is not enough. The supplier should separate the properties of Eurothane Silver from the assessment of the complete roof system.

Layers that should not be omitted

For a building with a defined roof geometry and mode of use, the vapour control layer and the waterproofing must be selected for the conditions prevailing beneath the covering. The gas-tight surface of Eurothane Silver alone does not eliminate leaks that arise at joints and where elements penetrate the building envelope.

At the parapet and at service penetrations, specify the terminations of the waterproofing and the vapour control layer separately. The extent of each of these layers must follow from the correct detail; their accidental direct connection should not be assumed. The gas-tight Eurothane Silver foil does not seal the gaps between boards. The offer should specify the upstand of the covering, the routing of the vapour control layer, the materials for sealing penetrations and the responsibility for execution.

Acceptance in line with the scope of the order

The specification should identify Eurothane Silver by thickness, edge type and intended covering system, because PIR boards of similar appearance may have a different range of application or different mechanical characteristics. Only a product described in this way can be compared with the works included in the tender.

Compare insulation works with tenders covering the same roof system, because a similar mesh print does not prove suitability for the intended covering. Assess the equivalence of a Silver substitute by facing and application, not only by thermal parameters — only then can you relate the purchase cost to the completed works. When approving the order, check the full name Eurothane Silver, the thickness, the side profile and the works involved in closing the roof, and record each excluded item as a separate cost.

With Eurothane Silver, do not compare the large and small format solely by price per square metre. What matters is availability at the chosen thickness, the cutting layout and the organisation of delivery to the roof. In the current data sheet, only the smaller format is specified for the 20 mm variant. The straight edge or rebate also has to be agreed. An unambiguous specification prevents material other than that envisaged in the works schedule from being priced.

7 branches. Materials closer to your project.

Izoprofil.com map of seven branches offering sandwich panels, PIR boards and sheet metal
  • SEROCK — Dzierżenin 34 E [mapa]
  • BŁONIE — ul. Sochaczewska 138A [mapa]
  • RADOM — ul. Grobickiego 8 [mapa]
  • ŁÓDŹ — Natolin 8 [mapa]
  • OLSZTYN — Barczewo, ul. Prosta 9 [mapa]
  • WROCŁAW — ul. Jerzmanowska 10C [mapa]
  • GORZÓW WLKP. — ul. Zielona 33/34 [mapa]

Check prices and availability: +48 500 409 109

Free quote