About PiVi

This author has not yet filled in any details.
So far PiVi has created 1504 blog entries.

A fence picket sample before purchase: what to check beyond colour?

A sample is one of the most useful elements when choosing a fence. It shows more than a photograph, but it also has limitations. A short section does not prove how a long picket will behave within a bay. It is therefore worth using it for the right tasks. Checking the colour, geometry, reverse side and finish helps you order metal fence pickets that meet expectations. The material should correspond to the offer, not just to the general product family. Check the profile, coating and finish designation. If a sample of a different variant was shown, note that difference. A similar colour should not be treated as confirmation of all the properties of the picket being ordered.

By |2026-11-15T18:58:56+01:002023-03-23|Knowledge base|Comments Off on A fence picket sample before purchase: what to check beyond colour?

Stone-coated or painted steel roof tiles: what does the finish change?

The choice between a granular-coated metal roof tile and a coated finish depends on the desired appearance and verified documentation, not on a slogan about a better covering. It is worth checking whether the sample matches the effect on a large roof area, and comparing the coating build-up and installation requirements. The granular finish gives a mineral texture and diffuses light, but does not replace insulation or snow guards. A coated finish allows various gloss levels and profiles. The decision should be based on a complete system for the same roof geometry.

By |2026-11-14T20:15:01+01:002023-03-14|Knowledge base|Comments Off on Stone-coated or painted steel roof tiles: what does the finish change?

What should a thermal and moisture report for a PIR wall include?

A thermal and moisture report helps select the layers of a building element if it describes the actual wall and its conditions of use. A green result in the calculator alone does not explain the behaviour of corners or the effects of leaks. For new construction, it is worth preparing the data so that the calculations can also be used when coordinating windows, installations and the sequence of works. A wall separating a flat from the outside performs differently from a building element between a workshop and a cold store. Record the design temperature on both sides, the heating method and the expected humidity. In a bathroom, laundry and utility room, the sources of vapour behave differently from those in a bedroom. It is also important whether the heating will operate continuously.

By |2026-11-14T10:38:08+01:002023-03-09|Knowledge base|Comments Off on What should a thermal and moisture report for a PIR wall include?

Selecting T18 or T35 trapezoidal sheets for a façade

The choice between T18 and T35 trapezoidal sheet for a façade depends primarily on the designed support layout, wind load and the intended appearance. Readers should check whether the sheet will form the external wall cladding or part of another enclosure system, and should examine steel thickness, coating and fixing. The lower T18 profile gives a more delicate surface rhythm, while the higher T35 produces a stronger relief and more pronounced light and shadow. The designation alone does not determine load capacity, so a matching system and specified material variant should be used together, not random sheets with a similar name.

By |2026-11-14T20:13:45+01:002023-03-08|Knowledge base|Comments Off on Selecting T18 or T35 trapezoidal sheets for a façade

Thermano ETICS quotations: what the complete system price should include

The Thermano ETICS quotation should reflect the complete façade. The insulating material is only one of the items. A reliable comparison also covers wall preparation, fixing, the reinforcing layer, render and the detailing of window sills and corners. Thermano ETICS is a composite board made of PIR with an outer layer of EPS 20 mm thick. The PIR part has gas-tight multilayer facings incorporating aluminium. An enquiry about PIR boards should describe the cross-section of the façade board with a PIR core and an outer layer of EPS 20 mm thick. The surface of Thermano ETICS must be recognised as the outer EPS layer belonging to the composite.

By |2026-11-16T02:21:40+01:002023-03-05|Knowledge base|Comments Off on Thermano ETICS quotations: what the complete system price should include

Comparing the weight of roof coverings: what belongs in the calculation?

Thin metal sheet coverings are among the lightest roofing options, but compare the mass of the whole system rather than the sheet alone. Check whether the data in the product sheet refer to a square metre of total area, effective coverage or a single sheet, as these are different units. Convert both coverings to kilograms per square metre of effective coverage and add ridges, flashings and accessories separately. Remember that profiling changes stiffness and the amount of material per roof area, and the load table must match the ordered variant. Leave the final selection decision to the designer.

By |2026-11-14T23:57:32+01:002023-03-03|Knowledge base|Comments Off on Comparing the weight of roof coverings: what belongs in the calculation?

What to check before insulating a tenement building from the inside

Preserving the historic façade may direct attention to internal insulation. In a tenement building, however, this is not a simple substitute for external insulation. Old walls, timber elements and different ways of using the flats require a joint assessment. The choice of PIR should result from an appraisal of the building, not be the first decision in the works plan. The inability to alter the façade does not automatically mean freedom to remodel the interior. The scope of the building's protection, the required approvals and the impact of the works on common parts must be checked. Original plaster, stucco, joinery or other interior elements may also matter. The assessment should precede ordering the lining.

By |2026-11-14T10:38:38+01:002023-02-25|Knowledge base|Comments Off on What to check before insulating a tenement building from the inside

How to choose the colour of a corrugated roof to suit its surroundings?

The roof colour is best assessed together with the building form, the façade and the landscape. Corrugated fibre cement sheets have a pronounced profile that changes how the colour is perceived through light and shadow. Asbestos-free fibre cement should be chosen on the basis of a real sample. A small rectangle of colour on a screen does not show what will be visible across the whole roof slope. In an open landscape the roof may be visible from a great distance. In dense development it is more often viewed up close, between the neighbours' façades. It is worth checking both points of view. The same shade can be a calm background in one place and a strong accent in another. Lasting features of the plot also matter: trees, paving, fencing and the colour of neighbouring buildings.

By |2026-11-15T19:00:47+01:002023-01-28|Knowledge base|Comments Off on How to choose the colour of a corrugated roof to suit its surroundings?

Matt or gloss coating for tile-effect metal roofing?

Choosing between matt and glossy metal roof tiles is not a simple matter of better versus worse — the type of coating, its properties and its intended use are what count. Before judging appearance, check corrosion and UV resistance, the metallic layer protecting the steel, and maintenance requirements. Compare specific data, not just the two finish names. View the colour outdoors, on several joined sheets, in sun and shade. Remember that durability also depends on the environment, installation and maintenance, and matching the look to the house makes sense only once the material meets the roof's technical requirements.

By |2026-11-14T16:51:48+01:002023-01-23|Knowledge base|Comments Off on Matt or gloss coating for tile-effect metal roofing?

IKO enertherm ALU TAP: how to check that a quotation is complete

With ALU TAP, the completeness of a quotation is decided not by the number of line items but by whether the tapered boards match the drainage layout plan. For each slope, the components must be specified and assigned to specific drainage areas, and the junction between areas draining in different directions must be listed separately. In your enquiry, describe the roof with aluminium-faced tapered boards at different slopes and the intended finished result, attaching the drainage layout plan showing slopes and heights. Also agree the terms for supplementary delivery, because a shortage of a few of the right parts can hold up the covering of a larger area.

By |2026-11-16T02:22:38+01:002023-01-06|Knowledge base|Comments Off on IKO enertherm ALU TAP: how to check that a quotation is complete
Back to top