Buying swissporPIR Alu: compare thermal resistance and scope of delivery

At a glance

Buying swissporPIR Alu requires comparing the material price with the work that will produce the finished building element. A lower board height can affect edge details and levels, but its value must be confirmed by the drawing and the full scope of execution. The product has a rigid polyisocyanurate foam core and a gas-tight laminate on both sides; the manufacturer lists aluminium, paper and polyethylene in the facing. The broader terms “polyurethane boards” and “polyurethane foam” do not replace the precise PIR designation. In an enquiry about delivery, specify swissporPIR Alu as a thermal insulation board with an aluminium, paper and polyethylene laminate, distinguishing it from the steel facing of a structural sandwich panel.

PIR board with printed grid and profiled edge when reviewing the scope of delivery of swissporPIR Alu

swissporPIR Alu PIR boards and the role of the laminate

The silvery surface of swissporPIR Alu does not mean that you are buying a load-bearing panel or a finished roof covering. In your enquiry, state its actual thermal insulation role. A cross-section showing the described support, protection and finish above and below the board allows bidders to price a comparable scope.

Selecting the thickness for the required thermal resistance

Compare the price of swissporPIR Alu for the specified thickness: at 100 mm the documentation assigns R_D 4.50 m²K/W, at 120 mm — 5.45, and at 160 mm — 7.25. The common thermal conductivity of these boards is 0.022 W/(m·K). Lambda alone therefore does not show the difference between the variants being priced.

Before comparing amounts, link the lambda of 0.022 to the specific thickness of the swissporPIR Alu being ordered. A cheaper item may produce a different effect, since the R_D of the insulation is not the U-value of the entire roof or wall. Before assessing the amount, compare the increase in thermal resistance together with the change in the height of the complete cross-section. In the quotation table, include the catalogue data for each variant and a separate calculation for the entire building component, and link the price difference to the specific change in parameters.

Polyurethane insulation in the right format

The formats 1200 × 600 mm and 2400 × 1200 mm and thicknesses from 20 to 300 mm are catalogue data; the availability of a specific combination of dimensions must be confirmed in the quotation. In the bill of quantities for the polyurethane insulation, include the swissporPIR Alu format and the edge profile for surfaces with many cut pieces.

The quantity of material ordered results from the geometry of the surface and the required cut pieces, not from the rectangular area alone — a large board does not guarantee little waste. Prepare the cutting plan so as to preserve the necessary terminations and continuity of joints. Attach to the quotation a laying plan, the covering area and confirmation of the availability of the dimension combination, so that the necessary details do not fall outside the scope.

Continuity at three-dimensional junctions

The thermal parameters of the board are decisive only in the regular field; junctions with other building components, edges and service penetrations can increase heat losses. Therefore, when assessing the completeness of the purchase, indicate the transition of swissporPIR Alu from the field to the edge and to the adjacent building component.

The continuity of swissporPIR Alu at the three-dimensional junction of building components must be included in the offer — increasing the thickness in the middle does not make up for the missing fragment at the perimeter. The delivery of supplementary materials should allow the board’s parameters to be used also at the locations where the layer terminates. Before approving the amount, agree the drawings of the edges, service penetrations and locations where the direction of the thermal insulation changes, as well as the scope of execution of the junctions.

CS, creep and service loads

For swissporPIR Alu, reaction to fire class E is declared, which does not make this material non-combustible. When proposing a substitute, compare the CS data of at least 150 kPa and CC(2/1.5/50)25 assigned to swissporPIR Alu.

Assessing an equivalent requires separating the CS data for swissporPIR Alu from creep under sustained long-term pressure. A matching name does not ensure equivalence, because the two parameters describe different conditions and are not interchangeable load limits. Based on the supplier’s data, select the build-up according to the duration of the pressure, and check the fire requirements separately, taking into account the product’s reaction to fire class E.

Insulation with polyurethane: cost of the material and of the whole system

Comparing offers requires matching thickness, edge profile and usable area. Determine the allowance after drawing out the cut pieces, and include in the budget a swissporPIR Alu offer with the same thickness, edge and function.

Compare the price of swissporPIR Alu with the work necessary to obtain a complete building envelope, because the amount for the material alone does not reflect the result, and a lower price per metre may involve a different thermal resistance or a narrower scope of supply. In the order, confirm the full designations, the quantities after cutting, and the cost of executing the details, and price any missing work separately.

A case worth considering

When comparing swissporPIR Alu offers, the price per square metre does not reflect the value of the solution in a tight detail. A thinner build-up may reduce the need to raise the flashings, which must be confirmed by measurement. The calculation includes preparation, fixing and surface protection, as well as cut pieces. The choice is determined by the total price of a correctly executed building envelope.

7 branches. Materials closer to your project.

Izoprofil.com map of seven branches offering sandwich panels, PIR boards and sheet metal
  • SEROCK — Dzierżenin 34 E [mapa]
  • BŁONIE — ul. Sochaczewska 138A [mapa]
  • RADOM — ul. Grobickiego 8 [mapa]
  • ŁÓDŹ — Natolin 8 [mapa]
  • OLSZTYN — Barczewo, ul. Prosta 9 [mapa]
  • WROCŁAW — ul. Jerzmanowska 10C [mapa]
  • GORZÓW WLKP. — ul. Zielona 33/34 [mapa]

Check prices and availability: +48 500 409 109

Free quote

Materials for your project