Choose a material

Roofing sheets

Sandwich panels

PIR insulation boards

XPS

Accessories

Fencing

PIR insulation

IKO enertherm ALU: comparing quotes for the same result

At a glance

The purchase of IKO enertherm ALU must be based on the full designation of the variant and its intended use in the building element, because a merely similar laminate does not confirm compliance with the design. In the enquiry, state the assembly with aluminium-faced PIR boards and the intended execution result, and in the pricing allow for the thickness, edge, parameters and installation. A difficult point is the penetration of services through the continuous insulation layer, so do not price only the easy field. Include a section drawing that identifies the exact ALU product and shows all necessary protective layers.

Upright silver-faced board, accompanying the IKO enertherm ALU guide — Izoprofil.com

The subject of the purchase must be unambiguous

The measurement should cover the thickness of the layer and the position of elements penetrating the insulation, so that the supplier does not have to guess the scope. You can only rely on the board’s thermal resistance if you maintain the application conditions of the entire system. Clarify the joints with the designer of the building envelope before comparing quotes by final amount, indicating the specific ALU variant.

The correct product and the scope of its data

In the IKO enertherm ALU specification, a distinction must be made between the data for the core and for the whole board. The PIR core has over 95% closed cells, and the aluminium facing on both sides contributes to the product’s properties. The declared λD is 0.022 W/(m·K), compression at least 175 kPa at 10% deformation. The board alone has reaction-to-fire class F, whereas B-s2,d0 refers to the specified end use on a steel substrate; the classifications are not interchangeable. In the order, the full name IKO enertherm ALU replaces generic “polyurethane boards”, and installation means factory-made boards in a defined layer build-up.

An identical basis of calculation

For 90 m², a 100 mm layer gives 9.00 m³, and 120 mm gives 10.80 m³, but the difference in volume alone does not determine the difference in the price of IKO enertherm ALU. Read the rates for thicknesses, packaging and cutting from the quotes; do not multiply the price of one board proportionally to the thickness. What matters is the lambda of 0.022 W/(m·K) for the defined product construction. A list of variant, thickness and scope of application organises the pricing; only then do the figures describe the same execution.

For IKO enertherm ALU, the reference point is the lambda of 0.022 W/(m·K) assigned to the defined product construction, not to any building envelope. The data for the board itself must therefore be separated from the results for the specified end use, and it must be checked whether the facing and edges correspond to the assumed building envelope. A cross-section with the full ALU designation and the required protective layers shows what the assumption refers to. The pricing should cover the variant, thickness and scope of application; otherwise the price relates to a different variant than the one required.

What changes the cost of the solution

In IKO enertherm ALU, selecting the thickness within a confirmed ALU system and changing the product variant with a reassessment of the joints lead to different scopes of work. Where services penetrate the continuous insulation layer, the consequences of both decisions must be set out, because this detail changes the scope. A classification from a test on a steel substrate cannot be transferred to any given building element, since the prices being compared would then rest on different assumptions. Differences in the cross-section are confirmed by the designer of the building element for the specific ALU variant, and choosing the cheaper item only makes sense once these have been clarified.

Labour hidden in the joint

With the aluminium facing of IKO enertherm ALU, the scope of substrate preparation and sealing of the joints depends on the building element selected. The offer should identify the board edge and the materials at service penetrations. The label confirms the delivery variant, while the application documentation and acceptance of the joints serve to verify that it has been used correctly.

Transport, stock and preparation

In the bill of quantities for IKO enertherm ALU, include the substrate preparation, cutting and protective layers appropriate to the application. Determine the quantity of boards from their dimensions and their layout on the building element. Changing the facing or the edge requires the joints to be checked and, where necessary, the auxiliary materials to be adjusted; do not assume that every change means a different number of boards.

Conditions for accepting the final quote

Acceptance of IKO enertherm ALU must be linked to a cross-section showing the full ALU designation and the protective layers. The variant label together with the documentation for the end use is to describe the same variant that was delivered. For service penetrations through the continuous insulation layer, the settlement of changes is determined, and the completeness of the scope is checked before signing. Where a substitution is proposed, the data for the board itself is kept separate from the results for the specified end use.

7 branches. Materials closer to your project.

Izoprofil.com map of seven branches offering sandwich panels, PIR boards and sheet metal
  • SEROCK — Dzierżenin 34 E [mapa]
  • BŁONIE — ul. Sochaczewska 138A [mapa]
  • RADOM — ul. Grobickiego 8 [mapa]
  • ŁÓDŹ — Natolin 8 [mapa]
  • OLSZTYN — Barczewo, ul. Prosta 9 [mapa]
  • WROCŁAW — ul. Jerzmanowska 10C [mapa]
  • GORZÓW WLKP. — ul. Zielona 33/34 [mapa]

Check prices and availability: +48 500 409 109

Free quote

Materials for your project