PIR insulation
When does the termPIR MAX 19 AL premium pay off in a renovation?
Paying extra for insulation makes economic sense when it brings a recognisable benefit. termPIR MAX 19 AL can reduce the thickness or improve the thermal resistance within the same space. In the cost estimate, this change must be shown alongside the cost of all accompanying works. termPIR MAX 19 AL is a board made of rigid PIR foam, protected on both sides with a gas-tight laminate of aluminium, paper and polyethylene. Its primary distinguishing feature is its level of thermal conductivity. An enquiry about PIR boards should describe the place where little space remains for insulation under the existing flashing. The cross-section at the existing flashing must be checked before taking advantage of the low lambda.

The precise scope of the enquiry
Do not choose solely on the basis of a short commercial description, because a very low lambda does not remove the restrictions relating to the substrate and adjacent layers. The offer being compared is intended to allow the advantage of the thickness to be used where it actually simplifies the detail. Agree with the tenderers the available section height and the scope of work needed to increase it, so that everyone prices a similar task.
An equal thermal basis for comparison
The declared value for termPIR MAX 19 AL is a lambda of 0.019 W/(m·K) across the thickness range of 80–220 mm. It is precisely this low thermal conductivity that allows a thinner insulation layer to be used while the required thermal resistance remains unchanged.
For comparison, take a thermal resistance of 5.0 m²K/W from the calculation example and check whether the thickness of termPIR MAX 19 AL corresponds to a variant that is actually available for delivery. The product of R and lambda gives a theoretical thickness that does not have to appear in the range, so the cheaper item may describe a different thermal effect. Select the nearest suitable thickness without attributing a specific U-value to the foam alone, and only after rechecking the entire building component relate the price difference to the parameters.
The board format and the actual waste
termPIR MAX 19 AL is available in three edge variants: FIT – straight edge, LAP – overlap, TAG – tongue and groove. The choice of variant is linked to the geometry of the board joint, not to the thermal parameters.
When planning the cutting layout, take into account the joint of the boards with the rebate above a place where the substrate has a slight unevenness, and do not force the laying over it. The material allowance results from the actual cutting layout, because the pack area can be misleading, and the TAG profile alone will not level the structure or close every imprecise joint. The quotation for the polyurethane insulation should cover the condition of the edges, the flat support under the joint and the actual width of any gap.
Is the proposed variant equivalent
For termPIR MAX 19 AL, CS(10/Y)100 and reaction-to-fire class E are declared. These two values should not be carried over from a board with a similar facing, because they relate to the specific product.
For a substitute, check the CS(10/Y)100 declaration assigned to termPIR MAX 19 AL, irrespective of the benefit of lambda 0.019, before you regard the lower price as a saving with an equal result. A similar name or facing is not enough, because better thermal insulation does not automatically mean greater load resistance. The supplier should present data on the performance requirements, and compare conformity with CS and class E against the documentation for the exact product being ordered in both solutions.
Layers that should not be omitted
The gas-tight laminate of termPIR MAX 19 AL restricts the flow of vapour through the surface of the board, but does not automatically seal the joints. Therefore the product itself requires protection during storage and installation, and the renovation cost estimate must include protection of the edges and connections.
In the quotation, identify the perimeter of the layer with the gas-tight facing at the point where installations pass through: the laminate must be connected to the sealing of the wall or penetration, and this item must not be omitted. For “polyurethane foam”, ask about the scope of protection, because a good thermal parameter does not close the path of air flow. Auxiliary materials are to complete this perimeter without relying solely on the metallised surface of the board. Before the final price, confirm the continuity of the sealing, protection during the break between work stages and responsibility for the protective measures.
Acceptance in line with the scope of the order
termPIR MAX 19 AL is available in formats 600 × 1200 and 1200 × 2400 mm, with a coverage correction resulting from the tongue and groove. Begin the comparison of offers by balancing the thermal effect, and only then relate the format and the resulting offcuts to the price.
Compare insulation works across the full scope of works: the cost difference between thinner insulation and rebuilding the surrounding elements. Both variants should deliver the same thermal effect and functional performance, so that the purchase price can be related to the completed works. A more expensive square metre of board is justified only by a specific benefit across the whole task, which is why the comparison separates the material price from changes to geometry, fixing and finishing. When ordering, check two complete calculations with the cutting plan and the consequences of the adopted layer thickness, and record each excluded item separately.
It is worth comparing the termPIR MAX 19 AL offer with the cost of a solution with the same required thermal resistance. Comparing a square metre of the same thickness alone answers a different question. If a thinner system allows rebuilding of the detail to be avoided, show this item separately. Do not assume such a saving without measurement. The purchase is easier to justify when it is known which specific element of the finished solution is paid for less or more.